# sk184479 - OSPF/BGP Fails to Start on Standby Security Gateway After ClusterXL Sync IP address Change

| Property | Value |
|----------|-------|
| Solution ID | sk184479 |
| Date Created | 2025-12-31 |
| Last Modified | 2026-01-15 |
| Technical Level | Advanced |
| Products | Security Gateway |
| Versions | R82.10, R82, R81.20 |

## Symptoms

- * OSPF/BGP fails to start on Standby Security Gateway after changing ClusterXL Sync interface IP address and subnet.

* Error message show in the */var/log/routed_messages* file:  

  `
  OSPF2 instance default OspfInterfaceUp(4625): not starting protocol on interface ...`

* Dynamic Routing configuration changes do not resolve the issue.

* Standby Security Gateway stays in a downed state with ROUTED PNOTE in **problem** state, for example:

  ```
  
  Registered Devices:
  
  Device Name: routed
  Registration number: 2
  Timeout: none
  Additional description: BGP interface Down -> Up transition
  Current state: problem
  Time since last report: 24.3 sec
  
  or 
  
  Registered Devices:
   
  Device Name: routed
  Registration number: 2
  Timeout: none
  Additional description: OSPFv2 Interface Down -> Up transition
  Current state: problem
  Time since last report: 823.7 sec
  ```

  <br />

* Rebooting the Standby Security Gateway alone does not resolve the issue.

## Cause

Protocol synchronization fails because the routed process does not reset its socket after Sync IP address change. As a result, OSPF/BGP sync fails and the standby cluster member remains down with a ROUTED PNOTE in problem state.

## Solution

This solution requires authentication. Please log in to view the full solution.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content