> Source: [sk183970](https://support.checkpoint.com/results/sk/sk183970)

# sk183970 - SNMP Alerting Not Supported in Smart-1 LOM/iDRAC (all versions) 

| Property | Value |
|----------|-------|
| Solution ID | sk183970 |
| Date Created | 2025-09-22 |
| Last Modified | 2025-10-26 |
| Technical Level | General |
| Products | Hardware |
| Versions | Not Version-Specific |
| OS | Gaia |
| Platform | Smart-1 |

## Symptoms

- The SNMP alerting option does not appear in the Lights-Out Management (LOM) Web User Interface (WebUI) of Quantum Smart-1 appliances.

## Cause

Smart-1 LOM does not support SNMP alerting by design.

## Solution

This is expected behavior.

Direct SNMP polling of the LOM/iDrac is not supported; you can use Gaia SNMP to query those sensors. For more information, see [sk90860](https://support.checkpoint.com/results/sk/sk90860).

---