# sk183528 - On 3600 and 3800 Appliances, SNMP "powerSupplyFailure" Trap Is Still Sent When Only One Power Adapter Is Configured

| Property | Value |
|----------|-------|
| Solution ID | sk183528 |
| Date Created | 2025-06-07 |
| Last Modified | 2025-06-09 |
| Technical Level | Advanced |
| Products | Hardware |
| Versions | Not Version-Specific |
| OS | Gaia |
| Platform | 3000 |

## Symptoms

- On 3600 and 3800 appliances, SNMP `powerSupplyFailure` trap is still sent when only one power adapter is configured.

## Cause

When you set `min_psu_set_by_user 1` as instructed in [sk166000](https://support.checkpoint.com/results/sk/sk166000), the alarm LED turns off even if only one power supply unit (PSU) is connected. However, the SNMP `powerSupplyFailure` trap continues to be sent. This happens because the SNMP trap logic was not updated to reflect the configuration change made in sk166000.

As a result, on 3600 and 3800 appliances, the system still generates a `powerSupplyFailure` trap when only one PSU is connected, even if `min_psu_set_by_user` is set to 1.

## Solution

This solution requires authentication. Please log in to view the full solution.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content