## Symptoms

- * The output of the `asg diag verify` command shows `Configuration files inconsistent`.

* The output of the `asg diag print ` command shows:

  ` < webuiparams:displaymode basic `

  ` --- `

  ` > webuiparams:displaymode advanced `

## Cause

When you change the view mode in the WebUI, it is not updated on all Security Group Members (SGMs) but only on the one to which you are connected.   

**Example** :  

1. On the Single Management Object (SMO), open the WebUI to the applicable Security Group.
2. On the top-left side, change **View mode** to **Advanced** or **Basic**.

SGMs attached to the Security Group do not show the change in their configuration. SGMs added after the change have the same setting as the SMO.  

![WebUI Image](https://sc1.checkpoint.com/sc/SolutionsStatics/sk181920/sk_Image (2)202401252109161.bmp)

<br />

## Solution

This solution requires authentication. Please log in to view the full solution.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content