> Source: [sk172343](https://support.checkpoint.com/results/sk/sk172343)

# sk172343 - Virtual Switch (VSW) Physical interface is not monitored by the cluster in Maestro/Chassis

| Property | Value |
|----------|-------|
| Solution ID | sk172343 |
| Date Created | 2021-03-03 |
| Last Modified | 2021-03-10 |
| Technical Level | General |
| Products | Security Gateway |
| Versions | R81 (EOS) |
| OS | Gaia |
| Platform | 41000 (EOL), 44000, 64000 |

## Symptoms

- * The physical interface of the VSW is not counted in "asg stat -v"

* Taking down the physical port connected to a Vswitch in the Active site/chassis does not trigger site failover.

## Cause

The *load_kern_params* is not run for VSW's , therefore, VSW's do not have relevant information about port priorities.

The cluster only monitors ports with a valid priority value. Therefore, the physical interface of the VSW is not monitored.

## Solution

This problem was fixed. The fix is included in:

* **[Check Point R81 for Scalable Platforms](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk169954)**
* **[R80.30SP Jumbo Hotfix Accumulator](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk165312) starting from Take 47**
* **[Jumbo Hotfix Accumulator for R80.20SP](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk155832) starting from Take 221**

If you choose not to upgrade, Check Point can supply a **Hotfix** . [Contact Check Point Support](https://www.checkpoint.com/support-services/contact-support/) to get a Hotfix for this issue.  
A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.  
For faster resolution and verification, please collect [CPinfo files](http://supportcontent.checkpoint.com/solutions?id=sk92739) from the Security Management Server and Security Gateways involved in the case.

Code was improved, and a kernel parameter was added.

1. Enable the following kernel parameter:

   **`g_fw ctl set int fwha_vsw_monitoring_enabled 1`**
2. Update the fwkern.conf to survive boot:

   **`g_update_conf_file fwkern.conf fwha_vsw_monitoring_enabled=1`**

No reboot is required after performing both steps.

**Important Note:** **This parameter must be enabled on all the members!**   
Different values between members can cause the cluster to be unstable!!

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content