> Source: [sk145372](https://support.checkpoint.com/results/sk/sk145372)

# sk145372 - ClusterXL member in down state with 'SIC failure' Pnote although SIC status is communicating 

| Property | Value |
|----------|-------|
| Solution ID | sk145372 |
| Date Created | 2019-01-22 |
| Last Modified | 2026-07-29 |
| Technical Level | Advanced |
| Products | Security Gateway |
| Versions | R82, R81.20, R81.10 (EOS), R81 (EOS) |
| OS | Gaia |

## Symptoms

- * ClusterXL member shows down state status with the following reason for state change :

  ```
  Event Code:CLUS-112600
  State change:INIT -> DOWN
  Reason for state change:FULLSYNC PNOTE - SIC failure
  ```

* SIC test between the Management server and the down member is "Communicating" .
* Sync interfaces connected via a switch .
* ClusterXL is down due to PNOTE: routed PIM Interface Down -\> Up transition

## Cause

The MTU of the Switch ports connected to the Sync interfaces is not identical.

## Solution