> Source: [sk112829](https://support.checkpoint.com/results/sk/sk112829)

# sk112829 - Hardware Sensors on 15000 and 23000 appliances show zero (0) values after completing the Gaia OS First Time Configuration Wizard

| Property | Value |
|----------|-------|
| Solution ID | sk112829 |
| Date Created | 2016-08-09 |
| Last Modified | 2018-01-08 |
| Technical Level | Advanced |
| Products | Security Gateway, Hardware |
| Versions | R82.10, R82, R81.20, Not Version-Specific |
| OS | Gaia |
| Platform | 15000, 3000 |

## Symptoms

- * Gaia Portal - *Maintenance* section - *Hardware Health* page shows:

  * all voltages - 0.00 Volt
  * all System Fan units - 0.00 RPM
  * all Power Supply units - Down

  *Example* :  
  [![](https://sc1.checkpoint.com/sc/SolutionsStatics/sk112829/sk112829_Gaia_Portal.png)](https://sc1.checkpoint.com/sc/SolutionsStatics/sk112829/sk112829_Gaia_Portal.png "Click the image to see it in full size in a new tab/window")
* Output of Clish command *show sysenv all output* on 15000 / 23000 appliance shows the following in the "Value" column:

  * all Voltages - 0.00 Volt
  * all System Fan units - 0.00 RPM
  * all Power Supply units - Down

  *Example* (output is truncated for brevity):

  ```
  
  Hardware Information
  
  Name        Value       unit          type     
  CPU0 Vcore   0.00         Volt          Voltage        
  CPU0 DDR4-1   0.00         Volt          Voltage        
  CPU0 DDR4-2   0.00         Volt          Voltage        
  VCC 12V      0.00         Volt          Voltage       
  VCC 3V       0.00         Volt          Voltage        
  VCC 5V       0.00         Volt          Voltage        
  3VSB         0.00         Volt          Voltage        
  5VSB         0.00         Volt          Voltage        
  VBAT         0.00         Volt          Voltage        
  CPU0 Temp    0.00         Celsius       Temperature           
  System Intake Temp   0.00         Celsius       Temperature           
  System Outlet Temp   0.00         Celsius       Temperature           
  System Fan 1   0.00         RPM           Fan        
  System Fan 2   0.00         RPM           Fan        
  System Fan 3   0.00         RPM           Fan        
  System Fan 4   0.00         RPM           Fan        
  Power Supply #1   Down         On/Off        Power        
  Power Supply #2   Down         On/Off        Power        
  BIOS         Valid        Valid/Invalid   BIOS     
  ```

* Output of Expert command *cpstat -f power_supply os* on 15000 / 23000 appliance shows that all Power Supply units are "Down":

  ```
  
  Power Supply
  --------------
  |Index|Status|
  --------------
  |  1  | Down |
  |  2  | Down |
  --------------
  ```

* Output of Expert command *cpstat -f sensors os* on 15000 / 23000 appliance shows:

  * all Temperatures - 0 degrees
  * all System Fan units - 0 RPM
  * all Voltages - 0 volts

  *Example* :

  ```
  
  Temperture Sensors
  -------------------------------------------------
  |Name       |Value|Unit     |Type       |Status |
  -------------------------------------------------
  |CPU1 Temp  |0    |degrees C|Temperature|      0|
  |CPU0 Temp  |0    |degrees C|Temperature|      0|
  |Outlet Temp|0    |degrees C|Temperature|      0|
  |Intake Temp|0    |degrees C|Temperature|      0|
  -------------------------------------------------
  
  Fan Speed Sensors
  -------------------------------------
  |Name        |Value|Unit|Type|Status|
  -------------------------------------
  |System Fan 4|0    |RPM |Fan |     1|
  |System Fan 3|0    |RPM |Fan |     1|
  |System Fan 2|0    |RPM |Fan |     1|
  |System Fan 1|0    |RPM |Fan |     1|
  -------------------------------------
  
  Voltage Sensors
  ----------------------------------------
  |Name       |Value|Unit |Type   |Status|
  ----------------------------------------
  |VBAT       |0    |Volts|Voltage|     1|
  |5VSB       |0    |Volts|Voltage|     1|
  |3VSB       |0    |Volts|Voltage|     1|
  |VCC 5V     |0    |Volts|Voltage|     1|
  |VCC 3V     |0    |Volts|Voltage|     1|
  |VCC 12V    |0    |Volts|Voltage|     1|
  |CPU1 DDR4-2|0    |Volts|Voltage|     1|
  |CPU1 DDR4-1|0    |Volts|Voltage|     1|
  |CPU0 DDR4-2|0    |Volts|Voltage|     1|
  |CPU0 DDR4-1|0    |Volts|Voltage|     1|
  |CPU1 Vcore |0    |Volts|Voltage|     1|
  |CPU0 Vcore |0    |Volts|Voltage|     1|
  ----------------------------------------
  ```

* PSU status LED on the front panel on 15000 / 23000 appliance is lit in amber.

* Alert status LED on the front panel on 15000 / 23000 appliance is blinking red.

* LOM WebUI - *Appliance Health* page might show:

  * all Voltages - 0.00 Volt
  * Case fan units - 0 RPM
  * Temperatures - 0 � C / 85 � C / 100 � C

  *Example* :  
  [![](https://sc1.checkpoint.com/sc/SolutionsStatics/sk112829/sk112829_LOM_WebUI.png)](https://sc1.checkpoint.com/sc/SolutionsStatics/sk112829/sk112829_LOM_WebUI.png "Click the image to see it in full size in a new tab/window")
* In some configurations (where one of the Power Supply Units is not plugged to a power outlet), */var/log/messages* file repeatedly shows:  

  `xpand[`*PID*`]: [ERR] i2c_smbus_read_byte_data STATUS_WORD 0x2848`

* Reboot resolves the issue only temporarily.

* The issue occurs after completing the Gaia OS First Time Configuration Wizard.

## Cause

Software driver collision causing appliance Hardware Health monitoring to report false zero sensor readings, regardless of actual sensors status.

Note: Symptoms are scoped to Hardware Health monitoring services and have no other effect on appliance functionality.

## Solution

This solution requires authentication. Please log in to view the full solution.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content