> Source: [sk110053](https://support.checkpoint.com/results/sk/sk110053)

# sk110053 - Reached End of Support - 5000 Appliances

| Property | Value |
|----------|-------|
| Solution ID | sk110053 |
| Date Created | 2016-02-10 |
| Last Modified | 2026-04-17 |
| Technical Level | General |
| OS | Gaia |
| Platform | 5000 |

## Solution

**Table of Contents**

* What's New in 5000 Appliances
* 5000 Appliances Downloads
* 5000 Appliances Known Limitations
* 5000 Appliances Documentation
* Notes
* Related solutions
* Revision History

For more information, see the [Check Point 5000 Appliance Product Page](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doShowproductpage&productTab=overview&product=470). You can also visit [Check Point CheckMates Community](https://community.checkpoint.com/) to ask questions or start a discussion and get our experts assistance.

What's New in 5000 Appliances {#New}
------------------------------------

Check Point 5000 series is giving businesses of all sizes the power to run the most comprehensive threat prevention capabilities.

From small businesses to large enterprises and data centers, these new purpose-built, optimized Security Gateway deliver all protections without compromising network performance, even when preventing threats in encrypted traffic.

Fully integrated security features include Firewall, IPS, Application Control, Anti-Virus, Anti-Bot, URL Filtering and the award-winning SandBlast Threat Emulation (Sandboxing) solution - all centrally managed by the gold standard in security management.

This new highly-optimized Security Gateway line delivers the highest real-world performance of all these advanced security features. With unmatched throughput, it provides maximum protection against known and unknown malware and zero-day threats without compromise. In addition, these new Security Gateways support your business's future growth by easily scaling to meet additional headcount and increased traffic demands.

Like our Security Gateways for large enterprises and data centers, these new Security Gateways include advanced enterprise-grade features such as Lights-Out-Management (LOM), which maximizes uptime and serviceability, as well as support for 1 GbE, 10 GbE and 40GbE I/O connectivity, managing the increasing volume of data and users. As a result, the new Security Gateways give you maximum power, full threat prevention and exceptional flexibility.

5000 Appliances Downloads {#Downloads}
--------------------------------------

**Note:** To download this package you will need to have a [Software Subscription or Active Support plan](http://www.checkpoint.com/services/techsupport/index.html).

|-----------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Download Package                                                      | Link                                                                                                                                                                                                  |
| Check Point R82 Image The models 5100, 5200 do not support ElasticXL. | See [sk181127](https://support.checkpoint.com/results/sk/sk181127)                                                                                                                                    |
| Check Point R81.20 Image                                              | See [sk173903](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk173903)                                                                    |
| Check Point R81.10 Image                                              | See [sk170416](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk170416)                                                                    |
| Check Point R81 Image                                                 | See [sk166715](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk166715)                                                                    |
| Check Point R80.40 Image                                              | See [sk160736](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk160736)                                                                    |
| Check Point R80.30 Image                                              | See [sk144293](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk144293)                                                                    |
| Check Point R80.20 Image for 5000 appliances                          | [![](https://sc1.checkpoint.com/sc/images/download-m.png "R77.30 Gaia Clean Install for 3000 / 5000 / 15000 / 23000 appliances")](http://supportcontent.checkpoint.com/file_download?id=72083) (ISO)  |
| Check Point R80.10 Image for 3000 / 5000 / 15000 / 23000 appliances   | [![](https://sc1.checkpoint.com/sc/images/download-m.png "R80.10 Gaia Clean Install for 3000 / 5000 / 15000 / 23000 appliances")](http://supportcontent.checkpoint.com/file_download?id=54509) (ISO)  |
| Check Point R80.10 / R77.30 Dual Image                                | [![](https://sc1.checkpoint.com/sc/images/download-m.png "R80.10 / R77.30 Dual Image for 3000 / 5000 / 15000 / 23000 appliances")](http://supportcontent.checkpoint.com/file_download?id=61594) (ISO) |
| Check Point R77.30 Image for 3000 / 5000 / 15000 / 23000 appliances   | [![](https://sc1.checkpoint.com/sc/images/download-m.png "R77.30 Gaia Clean Install for 3000 / 5000 / 15000 / 23000 appliances")](http://supportcontent.checkpoint.com/file_download?id=54340) (ISO)  |

**Notes:**

1. To install [Jumbo Hotfix Accumulator for R80.20](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk137592) on 5000 appliances, use Take 17, which became the default version on January 15, 2019.
2. To install [Jumbo Hotfix Accumulator for R77.30](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk106162) on 5000 appliances, use *Take 216* and higher.

3. Images for 5000 appliances support [SHA-256 based certificates](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk103839) for all blades and features:

   * Effective **March 2nd, 2017**, the same image is available for all 5000 models
   * Effective **February 16th, 2017**, image for 5100, 5900 appliances has been added
   * Effective **December 16th, 2016**, image for 5200, 5400, 5600, 5800 appliances has been replaced
   * Effective February 26th, 2016, images for Check Point R77.30 for 3000 / 5000 / 15000 / 23000 appliances and Check Point R80.10 / R77.30 Dual Image have been replaced, resolving [sk122612](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk122612).

To connect to the command line interface of the 5000 Appliances, a **Mini USB** can be used. To use the Mini USB console port, download and install the [5000 Appliances Mini USB console driver](https://supportcenter.checkpoint.com/supportcenter/portal/role/supportcenterUser/page/default.psml/media-type/html?action=portlets.DCFileAction&eventSubmit_doGetdcdetails=&fileid=51653) on the console client machine (desktop/laptop).  
The Driver Installation Guide in PDF format for each OS is added to the same archive.

5000 Appliances Known Limitations {#Limitations}
------------------------------------------------

The below table lists all of the 5000 Appliances specific known limitations.  

|-----------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| ID        | Symptoms                                                                                                                                                                                                                                                                                                                                                                                   |
| MBS-6583  | After installing an R80.20SP or R80.30SP image on a 5600 appliance, you must manually reboot the appliance.                                                                                                                                                                                                                                                                                |
| 01834483  | Interface LEDs for 40GbE line cards illuminate during reboot if a cable link is established, even if the interface is down.                                                                                                                                                                                                                                                                |
| 01923513  | When running the Hardware Diagnostic Tool twice consecutively, it always fails on the 40GbE self test in the second test. If multiple tests are required, reboot the device between tests.                                                                                                                                                                                                 |
| 01894982  | In CPView "Network/Interfaces" page, the link speed of 40GbE interfaces is displayed as *N/A* instead of *40GbE*.                                                                                                                                                                                                                                                                          |
| 01866405  | 40GbE line cards do not support auto-negotiation (although it is available in the Gaia Portal).                                                                                                                                                                                                                                                                                            |
| 01861839  | When running the Hardware Diagnostic Tool with a 40GbE line card without an external loopback cable, the output is not shown on the screen. Successful tests can be validated by viewing the hardware diagnostics log in */var/log/diagnostics* after reboot.                                                                                                                              |
| 02277321  | For all appliances except 5900: When using Solid State Drive (SSD), the local logging feature in SmartDashboard is not supported on the Security Gateway. In case of a disconnection between the Log Server and the Security Gateway, logs will automatically be saved locally on the Security Gateway.                                                                                    |
| -         | Solid State Drive (SSD) is supported with a Standalone Deployment only on 5900 appliances.                                                                                                                                                                                                                                                                                                 |
| -         | The size of the R80.10 / R77.30 Dual Image for these appliances exceeds the capacity of a DVD disc. Users should use the ISOmorphic Tool (build 160 and higher) from [sk65205](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk65205).                                                                                         |
| PMTR-9624 | "*invalid BIOS* " status in the WebUI on 5000 Enterprise Appliances. Refer to [sk138332](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk138332). * Resolved in [R80.10 Jumbo Hotfix Accumulator Take 185](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk116380) |

{#limitationsTable}

5000 Appliances Documentation {#Documentation}
----------------------------------------------

|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| [Check Point 5000 Appliances Quick Start Guide](http://downloads.checkpoint.com/dc/download.htm?ID=48891)                                                                                                                                                                                                                                                                              |
| [Check Point 5000 Appliances Getting Started Guide](https://sc1.checkpoint.com/documents/5000_GSG/English/html_frameset.htm) (English) [Check Point 5000 Appliances Getting Started Guide](http://downloads.checkpoint.com/dc/download.htm?ID=50944) (Russian) [Check Point 5000 Appliances Getting Started Guide](http://downloads.checkpoint.com/dc/download.htm?ID=50943) (Spanish) |
| [Check Point Appliances - Replacing Expansion Line cards](https://sc1.checkpoint.com/documents/Appliances/FRU_Line_Cards/Default.htm)                                                                                                                                                                                                                                                  |
| [Check Point Appliances - Installing Transceivers](https://sc1.checkpoint.com/documents/Appliances/FRU_Transceivers/Default.htm)                                                                                                                                                                                                                                                       |
| [Check Point 5000 Appliances Replacing AC PSU](http://downloads.checkpoint.com/dc/download.htm?ID=47307)                                                                                                                                                                                                                                                                               |
| [Check Point 5000 Appliances Replacing DC PSU](http://downloads.checkpoint.com/dc/download.htm?ID=50950)                                                                                                                                                                                                                                                                               |
| [Check Point 5000 Appliances - Installing LOM Card](https://sc1.checkpoint.com/documents/Appliances/FRU_LOM_Cards_5_6_7_15_23/Default.htm)                                                                                                                                                                                                                                             |
| [Check Point 3000 and 5000 Appliances Installing and Removing Memory](http://downloads.checkpoint.com/dc/download.htm?ID=47308)                                                                                                                                                                                                                                                        |
| [Check Point 5000 Appliances Rack Mounting Guide](https://sc1.checkpoint.com/documents/Appliances/Rails_5000_6000_7000_TE100X_Smart1405410/EN/Default.htm)                                                                                                                                                                                                                             |
| [Check Point 5000 Appliances Replacing Storage Devices](http://downloads.checkpoint.com/dc/download.htm?ID=54336)                                                                                                                                                                                                                                                                      |
| [Check Point 5000 Appliances R80.10 Image Management Guide (Dual Image)](https://sc1.checkpoint.com/documents/Appliances/PDF/CP_Appliances_R77.30_R80.10_ImageManagement.pdf)                                                                                                                                                                                                          |
| [Lights Out Management (LOM) Card Installation Guide for 5000, 6000, 7000, 15000, 23000 Appliances](https://sc1.checkpoint.com/documents/Appliances/FRU_LOM_Cards_5_6_7_15_23/Default.htm)                                                                                                                                                                                             |
| [Lights Out Management (LOM) Java-based Card Administration Guide for 5000, 6000, 7000, 13000, 15000, 16000, 21000, 23000, 26000, 28000 and Smart-1 225/3050/3150 Appliances](https://sc1.checkpoint.com/documents/Appliances/LOM_Java_Card_AdminGuide/Default.htm)                                                                                                                    |

Notes {#Notes}
--------------

* On 5800 and 5900 appliances, Lights Out Management (LOM) card is pre-installed.
* On 5100, 5200, 5400, and 5600 appliances, Lights Out Management (LOM) card is an optional accessory.

Related solutions {#Related solutions}
--------------------------------------

* [sk88064 - Check Point Appliances LOM Firmware versions map](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk88064)

Revision History {#Revision History}
------------------------------------

Show / Hide the revision history   

|--------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Date         | Description                                                                                                                                                                                                                                                                                                                                                                                                                |
| 26 Oct 2025  | Updated URLs in some of the links                                                                                                                                                                                                                                                                                                                                                                                          |
| 21 Oct 2024  | Added support for R82                                                                                                                                                                                                                                                                                                                                                                                                      |
| 29 Jan 2023  | Fixed the URL to sk88064 - Check Point Appliances LOM Firmware versions map                                                                                                                                                                                                                                                                                                                                                |
| 26 Jan 2023  | Updated link to "Installing LOM Card"                                                                                                                                                                                                                                                                                                                                                                                      |
| 19 Jan 2023  | Added support for R81.20                                                                                                                                                                                                                                                                                                                                                                                                   |
| 31 May 2022  | Updated links to "Replacing Expansion Line Cards" and "Installing Transceivers"                                                                                                                                                                                                                                                                                                                                            |
| 15 Jul 2021  | Added support for R81.10                                                                                                                                                                                                                                                                                                                                                                                                   |
| 10 Nov 2020  | Added support for R81                                                                                                                                                                                                                                                                                                                                                                                                      |
| 25 May 2020  | Added Check Point Appliances Lights Out Management (LOM) Card Administration Guide                                                                                                                                                                                                                                                                                                                                         |
| 17 Feb 2020  | Added support for R80.40                                                                                                                                                                                                                                                                                                                                                                                                   |
| 23 May 2019  | Added support for R80.30                                                                                                                                                                                                                                                                                                                                                                                                   |
| 16 Jan 2019  | Added the R80.20 image                                                                                                                                                                                                                                                                                                                                                                                                     |
| 26 Feb 2018  | Replaced images: * Check Point R77.30 for 3000 / 5000 / 15000 / 23000 appliances * Check Point R80.10 / R77.30 Dual Image                                                                                                                                                                                                                                                                                                  |
| 18 July 2017 | Added R80.10 / R77.30 Dual Image                                                                                                                                                                                                                                                                                                                                                                                           |
| 10 June 2017 | Added the R80.10 image                                                                                                                                                                                                                                                                                                                                                                                                     |
| 06 June 2017 | Added "R80.10 Image Management Guide (Dual Image)"                                                                                                                                                                                                                                                                                                                                                                         |
| 16 Feb 2017  | Added the R77.30 image for [3100](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk110052) / [5100](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk110053) / [5900](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk110053) Appliances |
| 16 Dec 2016  | * Replaced the R77.30 image for 5200, 5400, 5600, 5800 models to support [SHA-256 based certificates](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk103839) * Updated a note that the minimal supported Take of R77.30 Jumbo Hotfix Accumulator for 5200, 5400, 5600, 5800 models is Take_198                                                                |
| 31 Oct 2016  | * Replaced the R77.30 image for 5200, 5400, 5600, 5800 models to resolve [sk112829](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk112829) * Updated a note that the minimal supported Take of R77.30 Jumbo Hotfix Accumulator for 5200, 5400, 5600, 5800 models is Take_185                                                                                  |
| 06 Sep 2016  | Added Mini USB console driver for 5200, 5400, 5600, 5800 models                                                                                                                                                                                                                                                                                                                                                            |
| 28 Aug 2016  | Replaced the R77.30 image for 5200, 5400, 5600, 5800 models to provide support for Solid State Drive (SSD)                                                                                                                                                                                                                                                                                                                 |
| 03 Aug 2016  | Added: * "5000 Appliance Getting Started Guide (Russian)" * "5000 Appliance Getting Started Guide (Spanish)"                                                                                                                                                                                                                                                                                                               |
| 21 Apr 2016  | First release of this document                                                                                                                                                                                                                                                                                                                                                                                             |

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content