> Source: [sk107672](https://support.checkpoint.com/results/sk/sk107672)

# sk107672 - Outputs of "show sysenv all" and "cpstat os -f power_supply" commands show different status for Power Supply units

| Property | Value |
|----------|-------|
| Solution ID | sk107672 |
| Date Created | 2015-09-10 |
| Last Modified | 2019-05-07 |
| Technical Level | Advanced |
| Products | Security Gateway, Hardware |
| Versions | R82.10, R82, R81.20, Not Version-Specific |
| OS | Gaia |
| Platform | 3000 |

## Symptoms

- * Outputs of Clish command "show sysenv all" and Expert mode command "cpstat os -f power_supply" show different status for Power Supply units.

  *Example*:
  *

    ```
    
    HostName> show sysenv all
    
    ... ... ...
    Power Supply #1 Down
    Power Supply #2 Up
    ```

  *

    ```
    
    [Expert@HostName]# cpstat os -f power_supply
    
    Power Supply
    --------------
    |Index|Status|
    --------------
    |  1  |  Up  |
    |  2  | Down |
    --------------
    ```

* Issue started after turning off Power Supply unit #1.

## Cause

The "*cpstat*" command incorrectly creates the list of hardware sensors in reverse order.

## Solution