> Source: [sk104580](https://support.checkpoint.com/results/sk/sk104580)

# sk104580 - 'raid_diagnostic' command, SmartView Monitor,  'cpstat' command and  'snmpwalk' command show "MISSING" state for some harddisks

| Property | Value |
|----------|-------|
| Solution ID | sk104580 |
| Date Created | 2015-02-04 |
| Last Modified | 2018-02-09 |
| Technical Level | Advanced |
| Products | Security Gateway, Security Management Server, SmartConsole, Multi-Domain Security Management Server |
| Versions | R82.10, R82, R81.20, R82.10, R82, R81.20, R82.10, R82.10, R82.x, R82.20, R82.x, R82.20, R82, R81.20, R82.x, R81.20, R82, R82.20 |
| OS | Gaia |

## Symptoms

- * Output of "*raid_diagnostic* " command shows "`State:MISSING`" for one of hard disks.

  *Example*:

  ```
  
  [Expert@HostName]# raid_diagnostic
  Raid status:
  VolumeID:0 RaidLevel: RAID-1 NumberOfDisks:2 RaidSize:465GB State:OPTIMAL Flags:ENABLED
  DiskID:0 DiskNumber:0 Vendor:ATA      ProductID:WDC WD5003ABYZ-0 Revision:01.0 Size:465GB State:MISSING Flags:NONE
  DiskID:1 DiskNumber:1 Vendor:ATA      ProductID:WDC WD5003ABYZ-0 Revision:01.0 Size:465GB State:ONLINE Flags:NONE
  [Expert@HostName]# 
  ```

* Output of "*cpstat os -f raidInfo*" command shows:

  * In "Volume list" table":  
    Volume state = "0" (meaning *optimal* )   

  * In "Disk list" table:  
    Disk state = "1" for one of hard disks (meaning *missing*)
* SmartView Monitor shows:

  * In "RAID Volumes" table:  
    State = "*Optimal* "   

  * In "RAID Volume Disks" table:  
    State = "*Missing*" for one of hard disks

  [![](https://sc1.checkpoint.com/sc/SolutionsStatics/sk104580/SmartView_Monitor.png)](https://sc1.checkpoint.com/sc/SolutionsStatics/sk104580/SmartView_Monitor.png "Click the image to see it in full size in a new tab/window")
* Output of "*snmpwalk -c \<community\> -v 2c localhost 1.3.6.1.4.1.2620.1.6.7.7.2.1.9 1.0* " command on the problematic machine returns "1" for one of hard disks (meaning *missing*):

  `SNMPv2-SMI::enterprises.2620.1.6.7.7.2.1.9.1.0 = INTEGER: 1`

## Cause

Several harddisk devices were caught in the same query, which leads to reporting a "MISSING" state.

In the example below, the harddisk device with ID 11:0:0:0 and harddisk device with ID 1:0:0:0 were caught in the same query:

```
[Expert@HostName]# ls /sys/bus/scsi/devices/
10:0:0:0  11:0:0:0  1:0:0:0  2:0:0:0  9:0:0:0
[Expert@HostName]#
```

This can happen after plugging in and out USB devices, or after restarting the LOM card.

## Solution

This solution requires authentication. Please log in to view the full solution.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content