# sk1000296 - Syslog timestamps from Check Point Security Gateways appear inconsistent in Splunk

| Property | Value |
|----------|-------|
| Solution ID | sk1000296 |
| Date Created | 2026-10-20 |
| Last Modified | 2026-10-28 |
| Technical Level | General |
| Products | Security Gateway, Check Point Firewall |
| Versions | R82.10, R82.20 |
| OS | Gaia |

## Symptoms

- * Syslog events received in Splunk show inconsistent timestamps between Check Point Security Gateways.
* Some Gaia Operating System logs appear in the gateway's local time zone (for example, America/Chicago).
* Other logs appear to use different timestamp handling, resulting in inconsistent event times.
* Security Information and Event Management (SIEM) events may appear several hours before or after the expected time.
* The issue appears when Splunk receives syslog events from gateways running different Gaia releases.
* The time zone configuration on the Security Gateways appears consistent.
* Monitoring teams report that syslog messages from different Security Gateways do not use the same Request for Comments (RFC) 3164 timestamp format, so Splunk handles timestamps differently between sources.

## Cause

Starting with Gaia R81.20, Check Point uses **rsyslog** instead of the **legacy syslog** daemon.

This change affects the format of remote syslog messages. Gaia R81.20 sends remote syslog messages in standard [RFC 3164](https://www.rfc-editor.org/rfc/rfc3164.html) format. The timestamp in these messages uses the local time zone configured on the Security Gateway (for example, `America/Chicago`).

RFC 3164 timestamps do not include an explicit time-zone field. Because the syslog message does not include time-zone information, Splunk applies its own timestamp parsing rules. In this case, Splunk interpreted the received timestamp as UTC, resulting in an apparent time shift.

On older Gaia releases that used the legacy syslog daemon, Splunk commonly relied on message receive time rather than the event timestamp itself. As a result, timestamp behavior may differ between gateways running older and newer Gaia releases.

This behavior is expected and result from the transition from the legacy syslog daemon to rsyslog and the use of RFC 3164-formatted syslog messages.

The below examples show syslog messages sent from the R81.10 gateway, compared to R81.20.

*# tcpdump -nni any -vvv -A udp port 514*

![R81.10 packet capture](https://static.checkpoint.com/apps/sk/1000296/ea92b46a-0995-4f14-a67e-e79c0c0cddd9.png)

![R81.20 packet capture](https://static.checkpoint.com/apps/sk/1000296/7126e0bf-a168-4af7-923e-8ee852a90267.png)

## Solution

1. **Confirm the** **Gateway Time Configuration**

   1. On each affected Check Point Security Gateway, connect to Gaia Clish.
   2. Run these commands:

      ```bash
      show timezone
      show date
      show time
      ```

   3. Confirm that the Security Gateway uses the expected time zone, for example:

      ```text
      America/Chicago
      ```

   **Note:** Do not change the Security Gateway time zone if it is already correct.
2. **Configure timestamp handling in Splunk:**

   Configure Splunk to correctly interpret timestamps for the affected Check Point syslog source.

   Depending on operational requirements, use one of the following approaches:
   * Option A -- Interpret Events Using the Gateway Time Zone

     Configure the appropriate Splunk sourcetype or source

     Set the correct time zone for the affected source in `props.conf`, for example:

     ```text
     TZ = America/Chicago
     ```

     Replace the example timezone with the actual timezone configured on the gateway.

     Use this option when Splunk should display events according to the gateway's local time.
   * Option B - Use Message Receive Time

     Configure Splunk to use the log receive time, for example:

     ```text
     DATETIME_CONFIG = CURRENT
     ```

3. Use `TZ = <gateway time zone>` when Splunk must interpret the event timestamp according to the Security Gateway local time zone.

4. Use `DATETIME_CONFIG = CURRENT` only if the organization wants Splunk to use receive-time handling, which matches the behavior previously observed with Gaia R81.10 legacy syslog messages.

**Note:** The exact `props.conf` location depends on the Splunk deployment and app structure. Work with the Splunk administrator to apply the change to the correct Splunk parsing tier and configuration scope.

**Important:** **Do not modify Gaia `rsyslog` templates:**

* Do not manually edit this Gaia configuration file to resolve the issue:

```text
/etc/rsyslog.conf
```

* Gaia regenerates this file. Manual changes can be overwritten.
* Changing `rsyslog` templates is not supported through Gaia Clish for this use case.

**Verification:**

1. Send or wait for new syslog events from the affected Security Gateways.
2. In Splunk, confirm that new events from all affected Security Gateways show the expected event time.
3. Compare the Splunk event time with the Security Gateway time:

```bash
show timezone
show date
show time
```

4. Make sure that events no longer show the unexpected time shift, such as an approximate five-hour offset.
5. Confirm that all affected Security Gateways now use consistent timestamp handling in Splunk.

<br />

Additional Notes
----------------

Do not apply global Splunk timestamp changes without testing. Timestamp parsing affects incident investigation, compliance reports, and event correlation.

Coordinate the Splunk configuration change with the Splunk administrator or the relevant SIEM team.

Avoid unsupported manual changes to Gaia system files. Unsupported changes can be overwritten and can complicate future maintenance or support.

---

# Agent Instructions

This content is from the Check Point Support Center (https://support.checkpoint.com), the official knowledge base for Check Point cybersecurity products.

## Navigating This Knowledge Base

- **Complete index**: [llms.txt](https://support.checkpoint.com/llms.txt)
- **All SK articles**: [SecureKnowledge Sitemap](https://support.checkpoint.com/sitemaps/secureknowledge-sitemap-index.xml)
- **SK article URL pattern**: `https://support.checkpoint.com/results/sk/{skId}`
- **Markdown responses**: AI bot User-Agents automatically receive `text/markdown` content